Search
Push-insert technology installation module

multimod-F-G

Reactive power compensation components
multimod F 100 04 14 Gleit

The multimod-F-G installation module is a power factor correction module with push-insert technology.

The built-in modules are suitable for installing power factor correction systems in existing enclosures and are available for all enclosure systems available on the market. The individual components of the built-in modules with push-insert technology are attached to a mounting plate that can be pushed into the enclosure system like a drawer.

As KBR quality products, the modules impress with their long service life and individual production tailored to your specific application. The convenient modular design also enables simple and flexible system expansion. All compensation modules are available choked to prevent resonance damage and thus extend the service life of the capacitors.

Highlights
Technical data
  • Outputs from 10 to 100 kvar
  • Throttling factors 5.5, 7 or 8 % or 12.5 or 14 %
  • Capacitor rated voltage with 440 V or 525 V
  • For cabinet widths 600 or 800 mm
  • For cabinet depths 400, 500 or 600 mm

Device type: multimod-F – Reactive current compensation module, push-pull technology

GH p = 5.5, 7 or 8 %
Rated voltage | frequency:
Un = 400 V | 50 Hz
Maximum permissible operating voltage: Un = 400 V ± 10 %
Maximum permissible operating current: 1.2 xIn permanent
Switching element: Capacitor contactors
Control voltage: 230 V

>>> Control voltage transformer required for deviating operating voltage

Switching delay: 60 s
Capacitors:
Low-loss multicond UHPC power capacitors, MTK technology
Nominal capacitor voltage:
UBem. = 440 V
Discharge of the capacitors:
Discharge resistors t < 60 s, optional discharge chokes t < 3 s
Filter circuit chokes: Linear filter circuit chokes to avoid resonances in networks with harmonics,
Built-in temperature monitoring
Throttling factors: p = 5.5, 7 or 8 %
Module design:
Galvanized modular panels
Protection class:
IP 00, the components used comply with BGV-A2
Ambient temperatures: + 40 °C Maximum value, short-term
+ 35 °C in 24 hour average
+ 20 °C annual average
– 10 °C Lowest value
Protection:
Group fuse protection with NH fuses and fuse bases
(NH isolator on request)
Fittingly:
multimod-f_050_01-1000-14-08tb_

Built-in module with thyristors

multimod-f-050-01-14-steck_

Plug-in module plug-in technology

KBR
Support Team

We are happy to arrange
the contact to our
references and are available for
available for an interview.

Just get in touch with us.
Phone: +49 9122 6373-0
E-mail: info@kbr.de

Tablet mit Screenshot

Download

More information (brochures, user manuals, etc.) under download.