Search
Reactive power compensation on a mounting plate

Compensation system multimod-R

Reactive power compensation systems
multimod R 050 05 1220 07 80AH

For smaller structures, we offer the multimod-R, a power factor correction unit on a mounting plate.

This is fully wired and can be easily installed. The compensation unit contains a reactive power controller and is available choked and unchoked.

Highlights
Technical data
  • Outputs from 25 to 100 kvar
  • Throttling factor 5.5, 7 or 8% or 12.5 or 14 %
  • Capacitor rated voltage with 440 V or 525 V
  • Fully wired
  • Simple assembly
  • System with reactive power controller

 

Device type

AH p = 5.5, 7 or 8 %
AB p = 12.5 or 14 %
Rated voltage | frequency: Un = 400 V | 50 Hz
Maximum permissible operating voltage: Un = 400 V ± 10 %
Maximum permissible operating current:
1.3 x I n permanent
Reactive power controller:
multicomp 144 LCD
4-quadrant operation
Optimizing control behaviour
Circuit switching
Current transformer connection:
1 A and 5 A
Security and maintenance concept secureC: only in conjunction with multicomp 4D6
Switching element: Capacitor contactors
Control voltage: U tax = 230 V, 50 Hz
Control voltage transformer required for deviating operating voltage
Switching delay: 60 s
Capacitors: Low-loss multicond UHPC power capacitors, MTK technology
Nominal capacitor voltage: UBem. = 440 V (AH); UBem. = 525 V (AB)
Discharge of the capacitors: Discharge resistors t < 60 s; optional discharge chokes t < 3 s
Filter circuit chokes: Linear filter circuit chokes to avoid resonances in networks with harmonics, built-in temperature monitoring
Throttling factors: p = 5.5, 7 or 8 % (AH); p = 12.5 or 14 % (AB)
Built-in unit version: Galvanized mounting plates
Protection class: IP 00, the components used comply with BGV-A2
Ambient temperatures: + 40 °C Maximum value, short-term
+ 35 °C on a 24-hour average
+ 20 °C on an annual average
– 10 °C Lowest value
Protection: Group fuse protection with NH fuses and fuse bases
(NH isolator on request)

 

Fittingly:
multicomp-f144-3_

Reactive power controller 1-phase

secure-c_

Safety and maintenance module

multicab-r-400-8-14-gleit-offen_

Power factor correction system in the floor-standing cabinet

KBR
Support Team

We are happy to arrange
the contact to our
references and are available for
available for an interview.

Just get in touch with us.
Phone: +49 9122 6373-0
E-mail: info@kbr.de

Tablet mit Screenshot

Download

More information (brochures, user manuals, etc.) under download.