multicab-R-G

Reactive power compensation in a floor-standing cabinet

Reactive power compensation systems

multicab R 400 8 14 Gleit offen

The multicab-R-G compensation system provides you with high-quality, automatically controlled reactive power compensation in a floor-standing cabinet. With its standard dimensions, the floor-standing enclosure is compatible with any control room. If you require special dimensions, we are of course also flexible here.

Our standard are individually manufactured compensation systems that are explicitly designed for your specific application. This allows you to achieve reactive power compensation that is optimally tailored to your requirements. The convenient modular design also enables simple and flexible system expansion. All compensation systems are available detuned to prevent resonance damage and thus extend the service life of the capacitors. Systems without filter circuit reactors are also available, but not recommended.

KBR compensation systems are characterized above all by their quality and durability. We only use quality components in our handmade systems, most of which we develop and manufacture ourselves at our plant in Schwabach. The units have a temperature-controlled ventilation system that prevents damage to appliances due to overheating. In addition, the secureC safety and maintenance module and the automatic extinguishing system set new standards in terms of safety in compensation systems.

Highlights
Measures
Technical details
  • Outputs from 75 to 400 kvar
  • Detuning factors 5.5 / 7 / 8 % or 12.5 / 14 %
  • Capacitors multicond-UHPC with 440 V or 525 V
  • Reactive power controller multicomp D6 LCD with display
  • Simple system expansion thanks to push-insert technology
  • Optional: secureC © safety and maintenance concept and automatic extinguishing device

Dimensions (H x W x D in mm):

S4 (2000 x 800 x 400)
S5 (2000 x 800 x 600)

Voltage, current, frequency
multicab-R
Device type multicab-R SSGH p = 5,5 / 7 / 8 %
multicab-R SSGB p = 12,5 / 14 %
Rated voltage | frequency: Un = 400 V | 50 Hz
Maximum permissible operating voltage: Un = 400 V ± 10 %
Maximum permissible operating current: 1.3 xIn continuous
Reactive power controller: multicomp D6 with display
4-quadrant operation
Optimized control behavior
Circuit switching
Current transformer connection: Optionally available
Switching element: Capacitor contactors
Control voltage: Ucontrol = 230 V, 50 Hz
>>> Control voltage transformer required for deviating operating voltage
Switching delay: 180 s
Capacitors and filter circuit reactors
Capacitors: Low-loss multicond UHPC power capacitors, MTK technology
Nominal capacitor voltage: UBem. = 440 V (SSGH); UBem. = 525 V (SSGB)
Discharge of the capacitors: Discharge resistors t << 180 s
Optional discharge reactors t << 3 s
Filter circuit reactors: Linear filter circuit reactors to avoid resonances in networks with harmonics,
built-in temperature monitoring
Detuning factors: p = 5.5, 7 oder 8 % (SSGH); p = 12.5 oder 14 % (SSGB)
Details
Housing design: Sheet steel cabinet, interior and exterior paint finish RAL 7035 (other paint finishes on request),
Galvanized module panels, door hinge left (optionally right), bottom feed (on request from above), protection class I
Protection class: IP 20 (IP 54 on request), the components used comply with DGUV regulation 3 (on EN “DGUV rule 3”)
Ambient temperatures: + 40 °C Maximum value, short-term
+ 35 °C in 24-hour average
+ 20 °C annual average
– 10 °C Lowest value
Ventilation: Built-in roof ventilator, temperature-controlled
Fuse protection: Group fuse protection with NH fuses and fuse bases
(NH isolator on request)
Fittingly:

KBR
Support Team

We are happy to arrange
the contact to our
references and are available for
available for an interview.

Just get in touch with us.
Phone: +49 9122 6373-0
E-mail: info@kbr.de